The vertical alignment of this portable spectrophotometer means that it has a small footprint, perfect for small or curved surfaces.
The Konica Minolta CM-700d and CM-600d are vertically aligned portable sphere type spectrophotometers. For each measurement, data for specular component included (SCI) and excluded (SCE) are taken simultaneously to analyse the impact of surface conditions on measured colour.
The simple colour display and control pad means that the instrument is easy to integrate into processes and minimises the risk of operator error. Easy and intuitive user guidance in 6 languages guarantees maximum efficiency for daily colour quality control in the lab or the production line. The CM-700d offers an additional user selectable 3mm measuring aperture to further improve performance on small samples.
Model
CM-700d
CM-600d
Illumination/viewing system
di:8°, de:8° (diffused illumination, 8-degree viewing angle), d:8° (diffuse illumination/8° viewing angle), selectable SCI (di:8° specular component included) and/or SCE (de:8° specular component excluded) measurement. Conforms to CIE No. 15, ISO 7724/1, ASTM E-1164, DIN 5033 Teil 7, and JIS Z8722 Condition C standards.
Size of integrating sphere
Ø 40 mm
Detector
Silicon photodiode array (dual 36-element)
Spectral separation device
Diffraction grating
Wavelength range
400 nm to 700 nm
Wavelength pitch
10 nm
Half bandwidth
Approx. 10 nm
Light source
Pulsed xenon lamp (with UV cut filter)
Measurement time
Approx. 1 second
Battery performance
With alkaline dry batteries: Approx. 2000 measurements With nickel-metal-hydride rechargeable batteries (2300 mAh): Approx. 2000 measurements with full charge * Measured at 10-second intervals at 23°C; measurement fixed at SCI or SCE
Measurement/illumination area
MAV: Ø 8 mm / Ø 11 mm SAV: Ø 3 mm / Ø 6 mm * Changeable by replacing target mask and selecting lens position
MAV: Ø 8 mm / Ø11 mm only
Repeatability
Spectral reflectance: Standard deviation within 0.1%, Chromaticity value: Standard deviation within ΔE*ab 0.04 * When a white calibration plate is measured 30 times at 10-second intervals after white calibration
Inter-instrument agreement
Within ΔE*ab 0.2 (MAV/SCI) * Based on 12 BCRA Series II color tiles compared to values measured with a master body at 23°C
Display
2.36-inch TFT color LCD
Interfaces
USB1.1; Bluetooth® standard version 1.2*
Observer condition
CIE: 2° and 10° standard observer
Illuminant condition
CIE: A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (simultaneous evaluation is possible using two light sources)
Displayed data
Spectral values/graph, colorimetric values, color difference values/graph, PASS/FAIL result, color patch, color assessment
Color spaces
L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and color difference in these spaces (except for Munsell)
Colorimetric data
MI, WI (ASTM E313), YI (ASTM E313-73/ASTM D1925), ISO Brightness, 8° gloss value
Color difference formulas
ΔE*ab (CIE1976), ΔE*94 (CIE1994), ΔE00 (CIE 2000), CMC (l:c)
Storable data sets
Measurement data: 4000 sets/Target color difference data: 1000 sets
Power
4 AA-size alkaline dry batteries or nickel-metal-hydride rechargeable batteries; , Special AC adapter
Dimensions (W x H x D)
73 x 211.5 x 107 mm
Weight
Approx. 550 g (without white calibration cap and batteries)
Operating temperature/ humidity range
5 to 35°C; relative humidity 80% or less with no condensation
Storage temperature/ humidity range
0 to 45°C; relative humidity 80% or less with no condensation
Portable spectrophotometer with small footprint for measurement of small and curved solid samples.
Item Order Code: B027256
For perfect zero calibration. The black cavity tube prevents ambient light from entering the sensor during the calibration.
Item Order Code: A0E8-705
Target mask with glass protection plate to measure soft or wet samples. The protection glass plate prevents specimen from entering the instrument. The CM-A183 is also recommended for flattening soft specimen. The diameter of the measuring area is 8 mm and the size of disk is 40 mm in diameter.
Item Order Code: A0E8-706
Plastic cover and glass protected 8mm target mask to measure dusty materials with prevention of contaminating the instrument.
Item Order Code: A0E8-708
Item Order Code: A0E8-709
Required to fix opaque samples or the Glass or Disposal cells for measurement of opaque liquids in combination with the Sample Holder CM-A514. The clamp provides a constant pressure to the sample and the moveable side holders keep the cells in correct position.
Item Order Code: 1864-708
With the Sample Holder CM-A514 the instrument is set in horizontal position. Allows in combination with the Specimen Holder CM-A96 measurements of small samples up to a thickness of 22.5 mm or with the Glass- or Disposal Cells with 10 or 20 mm optical path the measurement of opaque liquids.
Item Order Code: B027152
For measurements of powders, paste and grains in combination with the Glass Cell CR-A504. The measuring head is set to up-side down position and the Cell Holder CM-A515 precisely fixes the position of the Glass Cell CR-504. To secure the instrument in a save position against tipping the Vertical Stand USD CM-A516 is recommended.
Item Order Code: B027153
Round cell made of optical glass (Diameter 34 mm) for measurements of powders, pastes, grains and small granular materials. For precise positioning, Cell Holder CM-A515 is recommended.
Item Order Code: 9970-2504
Stand to align the instrument in up-side-down position. Ideal to be combined with Cell holder CM-A515.
Item Order Code: B027154
Rectangular cell made of optical glass for precise transmittance measurement of transparent liquids. The optical path is 10 mm and recommended for liquids with normal optical density.
Item Order Code: 1864-710
Rectangular cell made of optical glass for high precision transmittance measurement of transparent liquids. The optical path is 20 mm and recommended for liquids with low optical density.
Item Order Code: 1864-711
Flow cell with 10 mm path for reflectance measurements of water based opaque liquids in combination with Sample Holder CM-A514 and Specimen Holder CM-A96.
Item Order Code: 9970-237
Rectangular disposal cell made of PMMA with an optical path of 10 mm. Suitable for transmittance measurements of water based transparent liquids. Recommended for liquids with normal density.
Item Order Code: 1870-716
Rectangular disposal cell made of PMMA with an optical path of 20 mm. Suitable for transmittance measurements of water based transparent liquids. Recommended for liquids with low density.
Item Order Code: 1870-717
For storing and hand carry the instrument and accessories.
Item Order Code: A0E8-604
Black glass tile with high gloss and absorption. Due to extreme long-term stability recommended as background standard.
Item Order Code: 9970-1109