Autoscan Spectrophotometer MYIRO-9

MYIRO-9 Measuring

--- ACCURACY AND RELIABILITY WITH SPEED ---

The key to success for a modern professional print business is automation and accuracy.

The MYIRO-9 Autoscan Spectrophotometer is the ideal tool for print colour management, combining speed, accuracy, ease-of-use and versatility.

Fast

  • 1500 patches in just 4 minutes
  • ISO13655:2017 M modes - M1, M0 and M2 in one single scan

Versatile

  • Measures virtually every chart including control wedges
  • Compatible with a wide variety of substrates
  • Virtual Fluorescence Standard for non-standard viewing environments

Connected

  • USB and Ethernet connection
  • QR code reader 

Accurate

  • Automatic wavelength calibration
  • Temperature drift compensation
  • Self-check function

Fast

The MYIRO-9 reads 1,500 patches in just 4 minutes and 2,500 patches in just 7 minutes. Within one single scan users obtain data for M0, M1 and M2, conforming to ISO13655:2017 and offering improved certainty of colours with papers containing OBA.

Connected

The MYIRO-9 features both USB and Ethernet connectivity enabling you to easily share one MYIRO-9 between multiple printing machines.

The colour display shows step by step instructions to the operator, improving usability and minimising the opportunity for user error. 

Accurate

Like the groundbreaking FD-7, the MYIRO-9 features built-in wavelength calibration and temperature drift compensation, maximising day-to-day accuracy and reliability.

Users can obtain amazing results and achieve the best possible neutral grey balance and flawless skintones in even non-standard viewing environments. Konica Minolta’s Virtual Fluorescent Standard (VFS) allows the creation of precise custom profiles to compensate for the environment where the print will be viewed.

Versatile

The MYIRO-9 uses a free-format-function enabling it to measure virtually every chart that might be used to calibrate printers and create profiles.

Even quality control wedges, used for conformance testing of proof prints, etc., can be measured with the MYIRO-9 without cutting them from the print.

 
Virtual Aperture

The MYIRO-9 can measure a wide range of substrates which makes it the ideal instrument for proofing, production and Large Format Printing applications. Thanks to its Virtual Aperture ability, user can obtain accurate and fast measurement also on structured and uneven materials. Users can decide about 1 measurement per patch, 2x2, 3x3 and up to 4x4 measurements per patch!

Virtual Aperture feature (left image) and Automatic Patch Detection (right image)

Automatic Patch Detection

The integrated image scanner enables automatic patch detection, automatic chart alignment and can read QR codes for fully automated sheet and chart identification.

Full Automation

Measuring a large number of patches with MYIRO-9 is both fast and convenient. Users who need to measure dozens of sheets every day can benefit from using the automatic sheet feeder, a first for a print colour measurement instrument. 

This optional accessory enables up to 100 sheets to be pre-loaded and measured with minimal user input. Combined with the QR code reader function, the measurement results can be automatically linked to the printed sheet.

All optional accessories can be purchased through our usual partner network.

MYIRO-9 optional automatic sheet feeder
MYIRO-9
MYIRO-9 Introduction video
Contact a MYIRO Partner

Get in touch

MYIRO devices, software, accessories and solutions are distributed via a worlwide network of color experts specialized in printing industry needs. Please select a region and we will guide you to our closest expert in color management solutions.

All of our partners are equipped with MYIRO-1 and/or MYIRO-9 with necessary software and skills, feel free to ask for information, quotation and demonstration of MYIRO products.

Download Area

MYIRO Color Management Software

Specifications

Our instruments are implemented in many software solutions.

Here you can check if your preferred software supports our instruments.

If you are missing a solution, please ask your vendor to contact us.

This list is a preliminary information. Please check with your software vendor to see if the functionality you need is supported.

MYIRO-9 compatibility list

Model

MYIRO-9

Illumination/viewing system

45°a: 0°(annular illumination) *1 
*1 Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil 7, ASTM E 1164 and JIS Z. 8722 Condition A for reflectance measurements.

Spectral separation device

Concave grating

Wavelength range

380 ~ 730 nm

Wavelength pitch

10 nm

Half bandwidth

Approx. 10 nm

Measurement area

Approx. Ø 3 mm

Light source

LED

Measurement range

Reflectance: 0 to 150%

Short-term repeatability

Colorimetric: Within σΔ E00 0.05 (Without polarization filter)
* Under Konica Minolta test conditions where a white calibration plate is measured 30 times at 10- second intervals after white calibration

Inter-instrument agreement

Within E00 0.3 (Average of 12 BCRA Series II colour tiles compared to values measured with a master body under Konica Minolta standard conditions; without polarization filter)

Measurement time

Approx. 4 min per 1,500 patches
*Konica Minolta measurement conditions*3

Output item

Spectral reflectance

Measurement conditions *2

M0 (A), M1 (D50) , M2 (A + UV filter), C, ID50, D65, ID65, F2, F6, F7, F8, F9, F10, F11, F12, User-defined light source

Backing condition

White backing, compliant with ISO13655 

Interface

USB2.0, 10Base-T/100Base-TX

Power

Specified AC adapter (Input: AC 100 to 240 V, 50/60 Hz; Output: DC 24 V, 5 A)

Size

MYIRO-9 only: W716 x D251 x H159 mm
Auto Sheet Feeder: W601 x D1,158
(when tray is open) x H245 mm

Weight

MYIRO-9 only: Approx. 10.5 kg

Operating temperature/
humidity range

10 to 35°C, 30 to 85% relative humidity with no condensation

Storage temperature/humidity
range

0 to 45°C, 0 to 85% relative humidity with no condensation

Standard accessories

AC adapter, USB cable, Measurement Utility software FD-S2w

Optional accessory

Auto Sheet Feeder FD-A09

Measurable Chart Specifications

Width

45 ~ 330mm

Length

170 ~ 1500 mm

Thickness

0.05 ~ 0.6 mm

Smallest patch size

6×6 mm

Maximum patches per sheet

1,394(A4)
2,928(A3)

*1  Unidirectional illumination for wavelengths of 400 nm and below
*2  M0, M1 and M2 are lighting conditions contained in ISO13655 “4.2.2 Illumination requirements and measurement conditions.”
*3  Chart size: A3, Patch size: 6 x 6 mm, Patch layout: 47 rows x 32 columns