Handheld digital luminance meter for measurement of light sources and reflected light.
The LS-150 and LS-160 are lightweight, compact and battery powered luminance meters for the measurement of a wide range of luminance conditions. Offering improved features and usability over their predecessors the LS-100 and LS-110. These instruments provide an increased measurement range up to 999,900 cd/m2 (LS-150) and 9,999,000 cd/m2 (LS-160) with improved V(λ) correlation (CIE relative photopic luminosity curve). The LS-150 also satisfies the criteria for DIN 5032-7 Class B.
Principal Applications
Model
Luminance Meter LS-150
Luminance Meter LS-160
Type
SLR spot luminance meter for measuring light-source and surface brightness
Acceptance angle
1°
1/3°
Optical system
85mm f/2.8 lens; SLR viewing system
Angle of view
9°
Relative Spectral Response
Closely matches the CIE spectral luminous efficiency V (λ)
Standard
Din 5032 Part 7 Class-B
Receptor
Silicon photocell
Minimum measuring area
Ø 14.4 mm (1.3mm)
Ø 4.5 mm (0.4mm)
Minimum measuring distance
1012mm (213mm)
Measurement modes
Luminance; difference luminance; peak/valley luminance or luminance ratio
Response time
Auto: 0.7 to 4.3s.
Manual: 0.7 to 7.1s.
Luminance units
cd/m2 or fL (switchable in menu)
Measuring range
0.001 - 999,900 cd/m2
0.01 - 9,999,000 cd/m2
Accuracy
Lv ±2%+2digit (below 1cd/m2)
Lv ±2%+1digit (above 1cd/m2)
Lv ±2%+2digit (below 10cd/m2)
Lv ±2%+1digit (above 10cd/m2)
(Illuminant A measured at ambient temperature of 20 to 30°C/68 to 86°F)
Repeatability
Lv ±0.2%+1digit
(Measurement subject: Illuminant A)
Temperature / humidity drift
0 to 40℃, RH85% or less (at 35℃)with no condensation
Flare characteristic
1% or less
Polarization error
Temperature dependence
0.2%/K or less
Calibration mode
Konica Minolta standard/user-selected standard (switchable)
Colour correction factor
Set by numerical input; range: 0.001 to 9.999
Reference luminance
10 ch; set by measurement or numerical input
Data memory
1000 Data
Display
External: Large multi digit LCD with backlight (with dimmer function) and additional indications
Viewfinder: 4 -digit LCD with LED backlight
Data communication
USB 2.0
Sync measurement
20 Hz to 400 Hz
Power source
Two AA size (1.5V) batteries, AC adapter (optional accessories) USB power bus
Operating temperature / humidity range
0 to 40°C, RH 85% or less (at 35°C) with no condensation
Storage temperature / humidity range
0 to 450C, RH85% or less (at 350C) with no condensation
Dimensions
71×214×154mm
Weight
850 g without battery
Standard accessories
Lens cap; Eyepiece cap; 2 AA-size batteries, Wrist wrap; Case, USB cable, Data management software CS-S20
Luminance meter for measurement of light sources and reflected light
Customers of Luminance Meter LS-150 or LS-160 can download the latest version of Data Management Software CS-S20 free of charge. Please read the Installation Guide included in the download file for the installation procedure.
Languages available: English, French, German, Italian, Spanish, Simplified Chinese, and Traditional Chinese
Item Order Code: 1852-711
Item Order Code: A8A8-710
Item Order Code: A8A8-711
Item Order Code: A80F-713