AeroDR 1012_image_1
AeroDR 1012_image_2
AeroDR 1012_image_3
AeroDR 1012_image_4
AeroDR 1012_image_5
AeroDR 1012_image_6

AeroDR 1012

Flat panel detector

  • Fits in incubators
  • Lightweight 
  • Can be shared between mobile and fixed room
AeroDR 1012_image_1
AeroDR 1012_image_2
AeroDR 1012_image_3
AeroDR 1012_image_4
AeroDR 1012_image_5
AeroDR 1012_image_6

Solutions

Solutions

Mobility

Hospitals and clinics are increasingly looking into ways to provide the best healthcare to all patients. Mobility is one such way to improve patient care because sometimes, care needs to come to the patient! Bedside exams may...

Functionalities

Functionalities

Functionalities

AeroDR 1012_image_2
  • Speed:

    Its improved cycle time allows you to do more exams per day and enables you to achieve a quicker diagnosis.

  • Capacitor

    With a charging time of only 30 minutes, the AeroDR Premium is completely charged from empty to full. With its unique capacitor technology, there is noloss of charging capacity and there is no need to replace it during the panel lifetime, like you would with e.g. Li-ion batteries.

  • AeroSYNC

    Using AeroSYNC, Konica Minolta’s X-ray detection technology, will enable you to easily retrofit existing mobile X-ray devices and X-ray rooms.

  • Robust

    The AeroDR is already known for having a high surface load (300 kg), making it suitable to be used with all types and sizes of patients.

AeroDR 1012_image_2

Features

Features

AeroDR 1012 Key Features

With the AeroDR 10”x 12” wireless flat panel detector, Konica Minolta offers an even greater scope of application. This panel is ideally suited for Neonatal and Orthopaedic examinations. Conformance to ISO standard dimensions allows the detector to be used in incubator trays for examination of newborn babies as well as in existing X-ray rooms without any modifications.

  • hc_feature_feather_icon

    Lightweight


  • hc_feature_battery_icon

    Capacitor


  • Fast throughout

    Speed


AeroDR 1012_image_1
  • hc_feature_AED_icon

    AED


  • hc_feature_weight_icon

    Robust


Specifications & Downloads

Specifications & Downloads
Detection Method Indirect conversion method
Scintillator CsI (Cesium Iodide)
Dimensions (WxDxH) 281.8 x 333.0 x 15.9 mm
Pixel size 175 μm
Weight 1.7 kg
Weight durability 150 kg @ ø 40 mm / 300 kg @ full image field
Communication Wireless LAN (IEEE802.11a compliant) / dedicated wired ethernet connection
Image preview time Less than 2 seconds
Cycle time Approx. 7 seconds (with dedicated wired connection)
Approx. 9 seconds (with wireless LAN connection)
Image field 1.404 x 1.696 pixels
Battery type Lithium Ion Capacitor
Battery charging time Empty to full within 30 minutes
Number of exposure images 146 images / 4.0 hours

Brochure AeroDR 1012

Get more information!
hc_AeroDR_1012_datasheet_thumbnail

Related hardware

Related hardware