Measuring Instruments

Spectrophotometer (spectral type)
NEW
Compact portable spectrophotometer with wireless communication and color LCD screen
Glass Cell made of optical glass for measurements of powders, pastes, grains and small granular materials. Diameter of the cell 34 mm. For precise positioning the Cell Holder CM-A515 is recommended.


Required to fix opaque samples or the Glass or Disposal cells for measurement of opaque liquids in combination with the Sample Holder CM-A514. The clamp provides a constant pressure to the sample and the moveable side holders keep the cells in correct position.
Glass Cell made of optical glass with an optical path of 10 mm. Recommended for precise measurements of opaque liquids in combination with Sample Holder CM-A514 and Specimen Holder CM-A96.
Disposal plastic cell with an optical path of 10 mm. Suitable for reflectance measurements of water based opaque liquids in combination with Sample Holder CM-A514 and Specimen Holder CM-A96.
Disposal plastic cell with an optical path of 20 mm. Suitable for reflectance measurements of water based opaque liquids in combination with Sample Holder CM-A514 and Specimen Holder CM-A96.

Glass Cell made of optical glass with an optical path of 20 mm. Recommended for precise measurements of opaque liquids in combination with Sample Holder CM-A514 and Specimen Holder CM-A96.
Small, compact and comfortable softcase for instrument body, white calibration tile and other small accessories.
Disposal plastic cell with an optical path of 10 mm. Suitable for reflectance measurements of water based opaque liquids in combination with Sample Holder CM-A514 and Specimen Holder CM-A96.
For precise zero calibration. The tube prevents ambient light from entering the sensor during the calibration. Reduces the influence of light reflected by dust particle in air to a minimum.


Target mask with glass protection plate to measure soft or wet samples. The protection glass plate prevents specimen from entering the instrument. The CM-A183 is also recommended for flattening soft specimen. The diameter of the measuring area is 8 mm and the size of disk is 40 mm in diameter.
Protects the instrument in dusty environments. The glass plate in front of the measuring port prevents dust from entering the instrument. Also suitable to measure wet and/or soft samples or to flatten fabrics.
Replacement dust cover for CM-A185.
For comfortable hand carrying and storage of the instrument and accessories.
Class 1 Bluetooth adapter for wireless communication for distances up to 100 m. USB A type connector. Supported by Windows Vista, XP and 2000.


Small, low weight Thermo-Printer for wireless printing out of measurement data via Bluetooth. Powered by rechargeable batteries, therefore also suitable for measurements in the field.

High gloss black glass tile with high absorption. Due to the extreme long term stability perfect to use as background standard.


With the Sample Holder CM-A514 the instrument is set in horizontal position. Allows in combination with the Specimen Holder CM-A96 measurements of small samples up to a thickness of 22.5 mm or with the Glass- or Disposal Cells with 10 or 20 mm optical path the measurement of opaque liquids.


For measurements of powders, paste and grains in combination with the Glass Cell CR-A504. The measuring head is set to up-side down position and the Cell Holder CM-A515 precisely fixes the position of the Glass Cell CR-504. To secure the instrument in a save position against tipping the Vertical Stand USD CM-A516 is recommended.

The CM-A516 Vertical allows to align the instrument in Up-Side-Down position and secures that the instrument cannot get out of balance by using the Cell-Holder CM-A515.

Recommended for the measurement of flat samples. The large base plate keeps the stability against mowing on the sample. The circular target area provides a precise positioning on the sample.
For measurements of powders, paste, grains or other small sized granular materials. The low reflectance glass plate protects the sample surface disorientations and prevents specimen material from entering the instrument.