Benchtop Colorimeter CR-5 to measure the colour of solid, pasty granular, and liquid samples either in reflectance or transmittance
Benchtop Colorimeter CR-5 with its transmittance chamber open to measure the colour of solid and liquid samples

CR-5

A benchtop colorimeter based on the CM-5, the chroma meter CR-5 offers a fantastic price to performance ratio, particularly for QC measurements of liquids. Like the CM-5, the CR-5 can operate independently of a PC and features a colour screen for enhanced usability.

  • Benchtop instrument with Top-Port alignment
  • Spectrally based Colorimeter
  • d:8° Sphere Geometry
  • Reflectance & Transmission
  • Stand-alone or PC Software operation
  • 3 Apertures SAV / MAV / LAV
Benchtop Colorimeter CR-5 to measure the colour of solid, pasty granular, and liquid samples either in reflectance or transmittance
Benchtop Colorimeter CR-5 with its transmittance chamber open to measure the colour of solid and liquid samples
The CR-5 is a versatile benchtop colorimeter based on the CM-5 spectrophotometer, ideally suited to colour quality control measurement of solid, granular and liquid samples either in reflectance (opaque samples) or transmittance (transparent or translucent samples).
 
The top facing measurement port, easily configured to either 3, 8 or 30mm, allows measurement of virtually all samples either directly or in petri dishes. The large transmittance chamber measures liquid samples in 2, 10 or 20mm cuvettes (dependent on the sample) or translucent solids. The CR-5 has the same simple user experience as the CM-5, but measures only tristimulus colour data in order to offer an unsurpassed price : performance ratio for QC measurements. Dependent on the user needs, the CR-5 can be configured to perform simple pass/warn/fail assessments of samples based on pre-configured targets and tolerances.

The CR-5 can be operated as a standalone instrument via the large onboard colour screen and user friendly firmware which facilitates setting of colour differences, tolerances and includes all major colorimetric systems including industry specific indices (Gardner, Hazen/APHA, Iodine, European and US Pharmacopoeia). When connected to a PC and Colibri ® or SpectraMagic NX colour data software, additional indices, user customisations and expanded options for storing, reporting and communicating colour data are available.

The CR-5 simplifies day to day colour measurement tasks and minimises the risk of operator errors via its simple and user-friendly user interface. Additional user centred features such as automatic calibration, Operator Wizard and seven operator languages reduce the training and processes required to obtain consistent and accurate colour data.

Features

Features
  • Versatility for a wide range of Applications

Combining the unique top facing measurement port with a range of accessories designed to maximise repeatability and ease of use, the CR-5 can measure the colour of virtually all samples in solid, granule or liquid form.

  • Large colour LCD

The large colour LCD is easy to read, greatly improves the user experience and can display measurement data numerically, graphically, or even just as PASS/FAIL judgments.

  • Wizard for on-screen operation guidance

The wizard function displays on-screen guidance for users to guide through the instrument set-up and measurement process.

  • USB storage of settings and data

Individual user configurations as well as target and measurement data can be easily stored on USB memory stick to allow multi-user capability.

Specifications & Downloads

Specifications & Downloads
Model Chroma Meter CR-5
Illumination/viewing system Reflectance de:8° SCE (diffuse illumination: 8° viewing, specular component excluded)
Conforms to CIE No. 15, ISO 7724/1, ASTM E 1164, DIN 5033 Teil 7, and JIS Z 8722 (Condition c)
Transmittance di:180° (diffuse illumination:180° viewing)
Integrating sphere size Ø 152mm
Detector Dual 40-element silicon photodiode arrays
Spectral separation device Planar diffraction grating
Light source Pulsed xenon lamp (with UV cut filter)
Measurement time Approx. 1 s (to data display/output); Minimum measurement interval: Approx. 3 s
Measurement/ illumination area Reflectance Changeable by changing mask and settings.
LAV: Ø30 mm/Ø36 mm; MAV (optional): Ø8 mm/Ø11 mm; SAV (optional): Ø3 mm/Ø6 mm
Transmittance Ø20 mm
Repeatability Chromaticity value: Standard deviation within ΔE*ab 0.04
* When a white calibration plate is measured 30 times at 10-second intervals after white calibration
Inter-instrument agreement Within ΔE*ab 0.15 (Typical)
(Based on 12 BCRA Series II colour tiles compared to values measured with a master body at 23°C)
Transmittance chamber No sides (unlimited sample length); Depth (maximum sample thickness): 60 mm Sample holder (optional) for holding sheet samples or containers of liquid samples can be installed/removed
Display 5.7-inch TFT colour LCD
Display languages English, Japanese, German, French, Italian, Spanish, Simplified Chinese
White calibration Automatic white calibration (reflectance)/100% calibration (transmittance) using internal white calibration plate
(Not available when using petri dish or transmittance cell)
Interfaces USB 1.1 (Connection to PC; USB memory stick); RS-232C standard (Connection to serial printer)
Observer 2° Standard Observer or 10° Standard Observer
Illuminant C, D65
Displayed data Colorimetric values, colour-difference values, colour-difference graph, pass/fail judgment, pseudo colour, colour assessment
Colour space L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and colour differences in these spaces (except for Munsell)
Index Reflectance

WI (ASTM E 313-73, ASTM E 313-96); YI (ASTM E 313-73, ASTM E 313-96, ASTM D 1925)

Transmittance Gardner, Iodine, Hazen (APHA), European Pharmacopoeia, US Pharmacopeia
Color-difference equation

ΔE*ab (CIE 1976), ΔE*94 (CIE 1994), ΔE00 (CIE 2000), ΔE (Hunter), CMC (l:c)

Pass/fail judgment Tolerances can be set to colorimetric values (except Munsell), colour-difference values
Storable data Sample data: 4,000 measurements; Target colour data: 1,000 measurements
USB memory stick storage Storage of measurement data and target colour data. Storage/reading of measurement condition settings
(Security-enabled USB memory sticks cannot be used.)
Power AC 100 to 240 V, 50/60 Hz (using exclusive AC adapter)
Size Slide cover closed: 385 (W) × 192 (H) × 261 (D) mm
Slide cover open: 475 (W) × 192 (H) × 261 (D) mm
Weight Approx. 5.8 kg
Operating temperature/
humidity range
13 to 33°C, relative humidity 80 % or less (at 35°C) with no condensation
Storage temperature/
humidity range
0 to 40°C, relative humidity 80 % or less (at 35°C) with no condensation
Specifications and appearance subject to change without notice. Company names and product names herein are trademarks or registered trademarks of their respective companies.

ACCESSORIES

ACCESSORIES

Optional accessories for CR-5

          

CM-A198 Transmittance Specimen Holder

Cell holder attachment for commercial rectangular cells (Macro type) with 12.5 mm width. Suitable for cells with an optical path of 10, 20 or 50 mm.

Item Order Code: A168704

 

CM-A96 Transmittance Specimen Holder

For precise positioning of transparent plates, films or other transparent samples for transmittance measurements. Holds the Rectangular Cells CM-A97 (2 mm path), CM-A98 (10 mm path), CM-A99 (20 mm path) and the Rectangular Disposal Cells CM-A CM-A130 (2 mm path), CM-A131 (10 mm path) and CM-A132 (20 mm path) or the Flow Cell CM-A508 (10 mm path) always in perfect and repeatable position for precise transmittance measurements of liquids.

Item Order Code: 1864-708

 

CM-A199 Transmittance Specimen Holder Attachment

Adapter to attach the Transmittance Specimen Holder CM-A96 in direction of the light receiving port.

Item Order Code: A168705

   

CM-A213 Transmittance Zero Calibration plate

The Transmission Zero Calibration Plate CM-A213 is required to block the light path for zero calibration in transmittance measurement mode. The black and mat coating of the plate absorbs also stray light within the transmission chamber of the instrument.

Item Order Code: A168717

   

CM-A97 Rectangular Cell 50 x 38, optical path 2 mm

Rectangular cell made of optical glass for precise transmittance measurement of transparent liquids. The optical path is 2 mm and therefore perfect for liquids with high optical density.

Item Order Code: 1864-709

   

CM-A98 Rectangular Cell 50 x 38, optical path 10 mm

Rectangular cell made of optical glass for precise transmittance measurement of transparent liquids. The optical path is 10 mm and recommended for liquids with normal optical density.

Item Order Code: 1864-710

   

CM-A99 Rectangular Cell 50 x 38, optical path 20 mm

Rectangular cell made of optical glass for high precision transmittance measurement of transparent liquids. The optical path is 20 mm and recommended for liquids with low optical density.

Item Order Code: 1864-711

   

CM-A130 Rectangular Disposal Cell 50 x 38, optical path 2 mm

Rectangular disposal cell made of PMMA with an optical path of 2 mm. Suitable for transmittance measurements of water based transparent liquids. Recommended for liquids with high density.

Item Order Code: 1870-715

   

CM-A131 Rectangular Disposal Cell 50 x 38, optical path 10 mm

Rectangular disposal cell made of PMMA with an optical path of 10 mm. Suitable for transmittance measurements of water based transparent liquids. Recommended for liquids with normal density.

Item Order Code: 1870-716

   

CM-A132 Rectangular Disposal Cell 50 x 38, optical path 20 mm

Rectangular disposal cell made of PMMA with an optical path of 20 mm. Suitable for transmittance measurements of water based transparent liquids. Recommended for liquids with low density.

Item Order Code: 1870-717

   

CM-A508 Flow Cell 50 x 38, optical path 10 mm

For continuous transmittance measurement of transparent liquids. The optical path of the cell is 10 mm and can be used with a pressure up to 0.8 Bar. The cell fits the Sample Holder CM-A96.

Item Order Code: 9970-237

   

CM-A195 Target Mask 3 mm

Target mask with 6 mm and 3 mm aperture for the measurement of small samples or to measure a limited area of the sample.

Item Order Code: A168-701

   

CM-A196 Target Mask 8 mm

Target mask with 11 mm and 8 mm aperture for the measurement of medium size samples or to measure a limited area of the sample.

Item Order Code: A168-702

   

CM-A202 Specimen Viewing Mirror

The mirror can be set in the transmission chamber and allows control of the position of the sample for reflectance measurements.

Item Order Code: A168-708

 

CM-A203 Target Mask for tube cells Ǿ 45 mm

Special Target Mask with a recess for precise positioning of the Tube Cells CM-A128, CM-30 and CM-50.

Item Order Code: A168-709

   

CM-A128 Tube Cell Ǿ 45 x 17 mm depth

The tube cell is made of optical glass with a diameter of 45 mm and provides a depth of 15 mm. The cell is suitable for reflectance measurements of opaque paste, powders, grains and granular materials. Fits to Target Mask CM-A203.

Item Order Code: 1870-712

   

CM-50 Tube Cell Ǿ 45 / 52 mm depth

The tube cell is made of optical glass with a diameter of 45 mm and provides a depth of 50 mm. The cell is suitable for reflectance measurements of opaque and slightly transparent paste, powders, grains and granular materials. Fits to Target Mask CM-A203.

Item Order Code: 1870-900

 

CR-A502 Tube Cell Ǿ 60 / 40 mm depth

The tube cell is made of optical glass with a diameter of 60 mm and provides a depth of 38 mm. The cell is suitable for reflectance measurements of opaque and very low transparent liquids, paste, powders, grains and granular materials. Due to the oversized diameter also suitable for specimens where edge loss effects occurs.

Item Order Code: 9970-220

 

CR-A506 Tube Cell Ǿ 60 / 60 mm depth

The tube cell is made of optical glass with a diameter of 60 mm and provides a depth of 58 mm. The cell is suitable for reflectance measurements of opaque and slightly transparent liquids, paste, powders, grains and granular materials. Due to the oversized diameter also suitable for specimens where edge loss effects occurs.

Item Order Code: B027166

 

CR-A504 Tube Cell Ǿ 34 / 35 mm depth

The tube cell is made of optical glass with a diameter of 34 mm and provides a depth of 33 mm. The cell is suitable for reflectance measurements of opaque and slightly transparent liquids, paste, powders, grains and granular materials. Due to the oversized diameter also suitable for specimens where edge loss effects occurs.

Item Order Code: 9970-216

   

CM-A210 White Calibration Plate

White tile for manual white calibration (instead performing the calibration with the build in white standard of the CM-5). The White Calibration Plate CM-A210 includes a CD with the spectral calibration values and a software to load the calibration data from a PC to the CM-5.

Item Order Code: A168-700

   

CM-A212 Calibration Glass Ǿ 45mm

Glass plate made of optical glass with the same optical properties as the bottom window of the Petri-Dish CM-A128. The Calibration Glass is recommended in case of manual tube cell calibration (instead performing the calibration with the build in white standard of the CM-5).

Item Order Code: A168-716

 

CM-A193 Accessory Case

For storage and protection of CM-5 accessories.

Item Order Code: A168-603

 

CM-A520 PET Pre-Form Holder

The PET-Pre-Form Holder CM-A520 allows a precise positioning of transparent Pre-forms in the transmission chamber of the instrument. The rail guide of the holder allows horizontal movements of the pre-form to define the area for the measurement.

Item Order Code: 9970-216

 

CM-A519 Retaining Ring (for CR-A506 Tube Cell Ǿ 60mm)

For precise and repeatable positioning of tube cells with 60 mm diameter.

Item Order Code: B027165

 

CM-A124 Zero Calibration Box

For precise zero calibration. The box prevents ambient light from entering the sensor during the calibration. Reduces the influence of light reflected by dust particle in air to a minimum.

Item Order Code: 1870-704

   

Thermo-Printer DPU-S245-01

Small and compact Thermo-Printer for immediately print out of measurement data.

Item Order Code: B027168

   

DPU-S245-01 Serial Connection Set

The set consist of the serial data cable with special plug for the data terminal of the printer body DPU-S245-01 and a 9-Pin Gender Changer to clamp the serial data cable of the printer with the serial data terminal of the instrument.

Item Order Code: B027169

   

CM-A58 Printer Cable

Serial Printer Cable with SUB-D9 plugs on both sides for connection between Thermo-Printer DPU-HS245 and instrument.

Item Order Code: 1854-730